Spring Roll Line Electricity and Operating Cost
A transparent worksheet that separates rated power, measured demand, energy and total operating cost.
Utilities: what is verified and what must be measured
| Utility | How to use it | Status |
|---|---|---|
| Installed/nameplate power | Electrical design input; do not report it as kWh/h | Verified per model page |
| Actual demand and energy | Measure during a defined FAT recipe and stable interval | Buyer/test team must measure |
| Voltage/frequency | Confirm ordered configuration and destination supply | Configuration dependent |
| Compressed-air pressure | 0.6-0.8 MPa on published complete-line models | Verified pressure; consumption unverified |
| Water and drainage | Derive from approved cleaning procedure and local rules | Buyer must confirm |
| Ambient range / IP rating | Do not assume tropical rating or IP65/IP66 | No verified public value |
Calculation framework
Estimated demand: nameplate kW × observed load factor. Energy: measured kW × hours. Electricity cost: kWh × tariff. Energy per 1,000 accepted pieces: total kWh ÷ accepted pieces × 1,000.
Illustrative calculation only: insert your own measured kW, hours, tariff and accepted output. This page does not present a SHENGXING measured energy result.
Test-condition worksheet
| Input | Value to record | Unit / evidence |
|---|---|---|
| Machine and configuration | _____ | Model/configuration sheet |
| Nameplate power | _____ | kW |
| Measured demand | _____ | kW, calibrated meter |
| Run time | _____ | hours |
| Accepted output | _____ | pieces |
| Tariff | _____ | currency/kWh |
| Labor and cleaning | _____ | people, hours, water |
| Wear parts | _____ | period and cost |
| Ambient / raw material | _____ | conditions and batch |
| Meter uncertainty | _____ | ±% |
Do not mix these terms
- Nameplate power: installed or rated load, not an hourly energy result.
- Measured demand: instantaneous or averaged real power during a defined test.
- Energy consumption per hour: kWh consumed in one operating hour.
- Energy per 1,000 pieces: kWh normalized by accepted output.
Frequently asked questions
Is nameplate kW the same as hourly consumption?
No. Use measured demand over a defined operating period.
Can I compare energy per piece between tests?
Only when product, accepted-output definition, run duration and conditions are comparable.
Does this page publish a measured saving claim?
No. It provides an illustrative calculation framework until approved test records are supplied.
What should a formal test record include?
Machine configuration, raw material, output, run time, ambient conditions, calibrated meter and uncertainty.